Kerr A, Arrowsmith M, Young S, Jaimes H, et al.
British journal of community nursing. Date of publication 2014 Dec 1;volume 19(12):585-91.
1. Br J Community Nurs. 2014 Dec;19(12):585-91. doi: 10.12968/bjcn.2014.19.12.585. Evaluation of a skin barrier cream for managing IAD in elderly patients using high-frequency ultrasound. Kerr A(1), Arrowsmith M, Young S, Jaimes H. Author information: (1)Senior Clinical Specialist (National Lead for Compression), 3M Health Care and Honorary Tissue Viability Nurse, Eastbourne. Incontinence-associated dermatitis (IAD) is a defined pathological entity and presents a significant burden for patients and health-care systems. The main objective of this evaluation was to test the efficacy and safety of a skin barrier cream in the management of uncomplicated IAD in elderly patients. Ten incontinent patients with mobility problems that presented with signs of IAD were included in the evaluation. The evaluation took place during a 2-week period. The product's efficacy was objectively evaluated in each patient with high-frequency ultrasound scans taken from the irritated skin compared with an ultrasound scan taken from normal adjacent (control) skin. Data analysis showed a statistical significance in favour of the capacity of the product to help reduce inflammatory signs. Photographic follow-up allowed correlation of ultrasound findings and clinical signs. The product was effective in treating the skin irritation and preventing further skin breakdown. There were no adverse events during the evaluation. DOI: 10.12968/bjcn.2014.19.12.585 PMID: 25475672 [Indexed for MEDLINE]
Appears in following Topics:
Incontinence Associated Dermatitis - Prevention and Management in Adults and Older Adults
t
-->